Raybond FR

RAYBOND®/FR is a fire-retardant ACM composed of aluminum skins and 70% mineral filled fire-retardant core. It passes most countries’ fire safety codes for exterior and interior, EN 13501-1, class B.

Due to its mineral-filled core RAYBOND®/FR meets the higher requirements of the fire classifications. It is hardly inflammable and offers all the proven product properties of the RAYBOND®/FR family, such as flatness, formability, resistance to weather and simple processing.

RAYBOND™ is therefore an ideal material for almost unlimited design possibilities for ventilated façades of any application.

Panel dimensions
Total Thickness: 3, 4 and 6mm
Width: 1000, 1220, 1250, 1500 (± 2 mm)
Length: max. 5800 mm (± 1.00 mm / m)


Technical Data

Method Unit RAYBOND®/FR
Physical Properties Thickness 4mmt
Specify Gravity 1.90
Weight kg/m2 7.6
Thermal Expansion ASTM D696 x 10-6/ºC 24
Thermal Conductivity Calculated Value W/m-K 0.45
Deflection Temperature ISO 75-2 ºC 116
Mechanical Properties of Composite Material Tensile Strength ASTM E8 MPa, N/mm2 49
0.2% Proof Stress ASTM E8 MPa, N/mm2 44
Elongation ASTM E8 % 5
Flexural Elasticity, E ASTM C393 GPa, kN/mm2 39.8
Sound Transmission Loss ASTM E413 STC 27
Metal Thickness with Equivalent Rigidity Calculated Value Aluminium 3.3mm

Fire Classification

Country Test Standard
EU (applicable in Europe, Switzerland and Turkey) EN 13823, EN ISO 11925-2, EN 13501-1
Great Britain BS 476 Part 6 & 7, BS 8414-1, BS 8414-2
Poland PN / B-02867
Czech Republic CSN 73 0862, CSN 73 0863
Hungary MSZ 14800-6:2009
Austria OENORM B 3800-5
Russia GOST 30244-94 method II, SNIP 21-01-97*, TsNIISK Natural Fire Test
USA NFPA 259-93 (British Thermal Unit), ASTM D1781-76 (Climbing Drum Peel Test), ASTM E-84 (Tunnel Test), ASTM E-108 Modified, UBC 26-9 & NFPA 285 (ISMA Test), ASTM E108 (Fire Test for Roof Covering), ASTM E119 (1-hr and 2-hrs Fire Rating), UBC 26-3 (Interior Room Corner Test), Combustion Toxicity Test New York State Uniform Fire Prevention and Building Code
Canada CAN / ULC-S 134-92 (Full-scale Exterior Wall Fire Test)
Japan ISO 5660-1 (Heat Release Test for Non-combustible Material)
China GB8625, GB8628, GB8627
Singapore BS 476 Part 6 & 7, Local fire regulation
Malaysia BS 476 Part 6 & 7, ISO 9705:1993, Local fire regulation